Valves
Pressure reducing valves (PRVs) reduce and hold downstream pressure steady, regardless of upstream pressure or flow variations. They are installed in valve chambers, sector inlets, and delivery points, and are one of the main tools for managing pressure in a water network. In its basic configuration a PRV needs no electrical power, which makes it suitable for remote chambers.
Excess pressure has operational consequences: it increases existing leakage, promotes bursts, and shortens the service life of pipes and connections, while also subjecting customers' installations to unnecessary pressure. By bringing pressure down to the level the service really requires, a PRV reduces pressure-driven losses and the number of failure events. It also improves service stability for customers.
Its performance is verified and adjusted with data: pressure loggers upstream and downstream show whether the valve maintains the expected pressure, and models with remote control allow it to be adjusted by time of day or by flow. Pressure management thus moves from a fixed setting to a process that can be measured, verified, and improved, and that supports decisions about where to install the next valve.
1 products available
Most water networks are designed to guarantee sufficient pressure at the most unfavorable point, which means that in other zones pressure is much higher than necessary. That surplus pressure is not harmless: it increases the flow lost through existing leaks, promotes new bursts, and accelerates wear on pipes, connections, and equipment. Pressure reducing valves exist to correct that imbalance.
A hydraulically operated PRV consists of a main valve and a pilot that regulates its opening according to downstream pressure. When outlet pressure rises above the set value, the pilot closes the valve; when it falls, the pilot opens it. The result is a stable outlet pressure, even when inlet pressure or flow varies during the day. In its basic configuration it needs no electrical power to operate, which makes it suitable for remote chambers.
Control can go beyond a fixed pressure. With accessories and controllers, the valve can operate at a different outlet pressure depending on the time of day, for example lower in the early morning, when demand drops and pressure tends to rise, or modulated according to flow to maintain adequate pressure at the critical point. Some configurations also allow remote adjustment, without visiting the chamber.
Installation design determines performance. The valve must be sized for the sector's real range of flows, not just the maximum flow; improper sizing can cause instability or cavitation. It is advisable to provide a strainer upstream, a bypass for maintenance, gauges at the inlet and outlet, and a chamber with safe access.
The value for the utility is twofold. On one hand, reducing excess pressure lowers pressure-driven losses and the frequency of bursts, which translates into fewer emergency repairs and longer asset life. On the other, it protects customers' installations and improves service stability. Typical applications are the inlet of district metered areas, sectors with elevation differences, pumping stations, and delivery points to large users.
Measurement is part of the solution. A pressure logger upstream and another downstream make it possible to verify that the valve holds the expected pressure, document behavior before and after the intervention, and estimate the effect on losses. The data can be integrated into a SCADA system or a district metering platform, and pressure reducing valves are a natural component of Marfel's Online District Metering solution, together with the flow meters and data loggers in the same offering.
The recommended path is to start with the sectors with the highest excess pressure or the longest history of bursts, instrument the inlet and outlet, and adjust based on the data. If you are evaluating pressure management for your network, Marfel's team can help you define installation points, sizing, and the control strategy.