Cellular 4G/2G pressure and flow data logger, IP68 submersible, with pressure surge detection and minimum night flow analysis using Pulse Interval Timing (PIT)

FloPath GTRI is a multiple-input cellular pressure and flow data logger manufactured by MOBILTEX, a Canadian company specialized in critical infrastructure monitoring. The FloPath brand groups MOBILTEX's pressurized water network monitoring line, formerly marketed as GCRTech, and focuses on reducing Non-Revenue Water (NRW) in distribution networks.
The unit stores data in 2 MB non-volatile Flash memory organized into up to 8 independent data files, each with its own logging parameters. A single input channel can feed several files with different data types (average, instantaneous, minimum and maximum), enabling fast logging such as step testing without interfering with the main 15-minute recordings.
Unlike conventional loggers, the GTRI detects pressure surges and measures minimum night flow more accurately through Pulse Interval Timing (PIT), which analyzes the interval between meter pulses rather than only their count. Its die-cast aluminum enclosure with IP68 protection is fully submersible, and its internal battery provides over 5 years of runtime under normal operation.
Data transmission uses an integrated cellular modem with 4G/5G LTE CAT M1 and NB-IoT options, plus 2G for legacy systems, supporting GPRS and SMS. Configuration, download and graphing are performed with the FPLog software, and local download is carried out through a non-contact IrDA infrared link.
| Specification | Value |
|---|---|
| PHYSICAL AND ENVIRONMENTAL | |
| Enclosure | Powder-coated die-cast aluminum |
| Dimensions | 87 mm (L) × 57 mm (W) × 38 mm (D) |
| Weight | 2.2 kg |
| Ingress protection | IP68, submersible |
| Operating temperature | -20 to 70 °C |
| POWER | |
| Battery | Internal, over 5 years of runtime depending on model and settings |
| Options | External battery pack (GA-EXTBATT1) and DC power |
| ANALOG AND DIGITAL INPUTS | |
| Standard channels | 1 to 4 selectable channels (2 flow and 2 pressure) |
| Pressure transducers | Internal or external (2 m cable), standard range 20 bar / 290 psi |
| Current inputs | 0–10 mA, 4–20 mA |
| Voltage inputs | 0–1 V, 0–10 V |
| Pulse rate | 80/s standard, up to 400/s optional |
| Compatible flow meters | Meters from all major manufacturers with digital pulse output (e.g. Elster, Actaris, Sensus) |
| DATA LOGGING | |
| Memory | 2 MB non-volatile Flash, 8 files of up to 60,000 readings each |
| Memory mode | Block or cyclic, with programmable start and stop |
| Data retention | 10 years if battery power fails |
| Sampling rate | Configurable from 1 second to 15 minutes |
| Logging interval | Configurable from 1 minute to 24 hours (cellular) |
| Data types | Average, instantaneous, minimum and maximum |
| Flow logging modes | Count and event (Pulse Interval Timing) |
| COMMUNICATION | |
| Cellular modem | Integrated: 2G, 4G/5G LTE CAT M1 or NB-IoT |
| Services | GSM data, GPRS and SMS |
| Local download | Non-contact IrDA infrared, 115,200 baud |
| Software | FPLog (programming, downloading and graphing) |
| ORDERING CODES | |
| Pressure | P (1 internal), Px (1 external), PP (2 internal), PxPx (2 external) or none |
| Flow | F (1 input), FF (2 inputs) or none |
| Cellular | 2G, 4GC (4G CAT M1), 4GN (4G NB-IoT) |
| Example | GTRI-PxFF-2G: 1 external pressure, 2 flow inputs, 2G cellular |
| Accessories | Flow input cable (GA1), coiled pressure hoses (CHP), female quick release (QFF), programming cable (COM1-25), external battery pack (GA-EXTBATT1) |
| GENERAL INFORMATION | |
| Manufacturer | MOBILTEX Data Ltd. (FloPath brand) |
| Country of manufacture | Canada |
| Warranty | Contact Marfel |